<LOGO>
FM Transmitter Measurement Report
Created: 2026-05-05 07-33-10
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 41 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 16 kHz 7730 0,4657
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,9 dBr 4,48 dBr 6,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 16 kHz MIN: 12 kHz % above 76 kHz: 0,4657 Acquired: 2026/05/05 7.32.06 Total samples: 7730 Equivalent time: 0:06:26 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 6,1 dBr MIN: 2,9 dBr AVE: 4,48 dBr % above 12,2 dBr: 0,0 Last value: 3,2 dBr (2026/05/05 7.32.05) 07.18 07.20 07.22 07.24 07.26 07.28 07.30 07.32 0 2 4 6 Pm [dBr]